FeaturedOpportunity Radar20,000+ opportunities tracked worldwide, filtered for your expertise.One-time report — $29 $9.90 →

ElumTools

AI-powered lighting calculation add-in for Revit

Fully integrated lighting analysis add-in for Autodesk Revit that performs point-by-point illuminance calculations using radiosity-based computation. Supports general, emergency, daylight, and horticultural lighting modes with interactive visualizations and intelligent fixture layout assistance.

Not publicly disclosed (acquired by Revalize in 2021) raised Established
Founded 1984 · Part of Revalize (8,000+ total customers); ElumTools customer count not publicly specified; used by architectural and lighting design firms globally

Why This Tool Exists

The Problem

Lighting designers manually compute illuminance values outside Revit using external tools like AGi32, requiring export of geometry, external calculations, and manual reconciliation with design drawings. This workflow adds 4-8 hours per project and breaks the BIM design process, increasing errors and design iteration time.

The Solution

ElumTools brings the proven AGi32 radiosity calculation engine directly into Revit as a native add-in. Designers calculate illuminance directly on Revit geometry using lighting families already in the model, eliminating export/import cycles and enabling real-time design feedback with Layout Assistant for automatic fixture placement optimization.

How You Use It

Delivery Method
SaaSDesktop Add-in
Integrations
Autodesk Revit 2020-2025Photometric databasesBlueBeam (via Revit export)AutoCAD (via IES export)
Disciplines
Architecture, MEP Engineering, Lighting Design
Project Phases
Schematic Design, Design Development, Construction Documentation
Project Types
Commercial, Hospitality, Healthcare, Institutional, Residential

Data Transparency

Exactly what this tool uses and how

Input
What it needs
Required: Revit project with lighting families, Room/Space definitions in model, Revit material definitions
Optional: Custom calculation grids, Photometric IES files, User-defined surface reflectances, Emergency fixture designation
Formats: RVT (Revit native), IES (photometric data), Material reflectance values
Output
What you get
Format: Interactive illuminance analysis reports with visualization overlays in Revit views
Fields: Point-by-point illuminance values (lux or footcandles), Luminance and exitance calculations, Unified Glare Rating (UGR) analysis, Emergency lighting coverage maps, Daylight factor and daylighting contributions, PPFD values for horticultural applications, Isolation contours and spatial maps, Fixture count and placement optimization recommendations
Algorithm
How it works
Model: AGi32 radiosity calculation engine (industry standard method for photorealistic lighting analysis)
Accuracy: Radiosity method provides photorealistic accuracy; specific accuracy metrics not publicly disclosed
Privacy
How your data is protected
Retention: Project data stored locally on user workstations; cloud access limited to Instabase photometric database
Training: Not publicly specified whether production project data used for model training
Compliance: Operates under Revalize compliance program, Follows GDPR principles, Aligns with SOC 2 and ISO 27001 standards (certification details not publicly available)
API
Integration
Endpoint: Not applicable (desktop add-in, not web service)
Method: Revit API (built as native add-in)

Use Cases

  • · Interior lighting design: Calculate illuminance on work planes and accent surfaces without external software; optimize fixture placement to meet lighting codes (IES, BS EN12464)
  • · Emergency lighting design: Toggle to Emergency mode to analyze backup lighting coverage and verify code compliance
  • · Daylight integration: Combine natural and artificial light calculations to optimize daylighting contribution
  • · Horticultural lighting: PPFD mode for greenhouse, plant growth, and vertical farm lighting design
  • · Hospitality design: Real-time visualization of accent and ambient lighting effects in conceptual and design development phases
  • · Code compliance verification: Automated checks against British Standard BS EN12464-1 for workplace lighting requirements

Pricing

Free
14-day free trial (full feature access, no credit card required)
Pro
$94/user/month (annual subscription via cloud-based licensing)
Enterprise
Not publicly specified; contact vendor for multi-user, perpetual license, or on-premise options
Website →
Research Sources & Data Quality Last verified: 2026-04-04
Verified Data (18)
problem, solution, deliveryMethod, integrations, disciplines, projectPhases, projectTypes, maturityStage, yearFounded, license, isOpenSource, input-formats, output-structure, algorithm-model, algorithm-approach, pricing, useCases, control-features
Not Found (9)
customerBase-specific-count, funding-total-for-LAI, api-endpoint-details, privacy-policy-specific-document, accuracy-percentage-metrics, soc2-certification-report, iso27001-certification-report, enterprise-pricing, algorithm-accuracy-validation-studies
Our Commitment: We only include verified data from official sources. If information isn't publicly available, we mark it as "Not publicly specified" rather than guessing.