Resource search

Search DataDrivenAEC

Open the full search page →

Entered-value methodsSource-labelledPlanning scopeFree tools

Building Energy
& Thermal Calculators

16 released calculators for bounded conversion, normalization, and entered-value comparisons. Each route states what it calculates and what it cannot establish.

16
Released calculators
Entered
Project/model values
Separate
Standards and schemes
No
Automatic certification

Energy Calculators

Choose the method matching your available evidence. Do not treat a conversion or entered-target comparison as a whole-building simulation, code check, or certification.

energy
Wall Assembly U-Value
Layer build-up (ISO 6946) → assembly R and U-value
Calculate →
energy
Condensation Risk
Temp + RH → dew point and surface condensation risk
Calculate →
energy
Thermal Bridge
Linear heat loss (Ψ·L·ΔT) + fRsi mould-risk check
Calculate →
energy
Roof U-Value
Insulation + layers (upward flow) → roof U-value
Calculate →
energy
Window U-Value
Glass + frame + edge → whole-window Uw (ISO 10077)
Calculate →
energy
Passive House Criteria
Selected PHPP/test values vs verified project criteria
Calculate →
energy
Solar Payback
Cost − incentives ÷ savings → payback period
Calculate →
energy
Embodied Carbon by Material
Σ (mass × A1–A3 factor) → cradle-to-gate kgCO₂e
Calculate →
energy
R-Value ↔ U-Value
Convert thermal R and U between SI and imperial units
Calculate →
energy
Spray Foam Coverage
Area + thickness → board feet, R-value, and sets to order
Calculate →
energy
Building Site EUI
Annual site energy ÷ matching floor area → EUI; comparison targets remain separate
Calculate →
energy
Annual Heating Demand
Completed model result ÷ matching area vs verified target
Calculate →
energy
Energy Demand
Completed model needs ÷ matching reference area
Calculate →
energy
U-Value
Homogeneous wall layers → series R-value and U-value; no automatic compliance verdict
Calculate →
energy
Daylight Factor
Room and window geometry → early-stage daylight-factor screening, not certification
Calculate →
energy
Window Size for Daylighting
Room depth + target daylight factor → minimum glazing area
Calculate →

Keep calculations, codes, and certification schemes separate

An arithmetic conversion, energy-model output, adopted energy code, and voluntary certification assessment answer different questions. The applicable baseline and evidence depend on jurisdiction, scheme, edition, project type, and selected compliance path.

  • Confirm the adopted energy code or named assessment scheme and its exact edition.
  • Use compatible model boundaries, floor-area definitions, fuels, units, weather data, and time periods.
  • Treat user-entered targets as inputs unless the method explicitly sources and selects them.
  • Use the complete governing method and qualified assessor where compliance or certification is claimed.
EUI and heating demand are not interchangeable

They can use different scopes, boundaries, floor-area definitions, and model procedures. Compare only values produced on a compatible basis and retain the source of every input.

A U/R conversion is not an assembly check