Onsite non-potable reuseVerified design inputs

Greywater Design-Basis
Balance Worksheet

Balance permitted daily greywater supply against eligible daily non-potable demand and compare provided storage with an independently engineered requirement.

Who it's for: plumbing engineers and sustainability consultants sizing greywater systems at construction documents.

Verified daily balance
same volume unit throughout

How to use this calculator

1
Establish permitted source and use
Confirm the jurisdiction, adopted provisions, water-quality treatment targets, and approval path.
2
Develop daily profiles
Use project-specific source and end-use calculations; averages do not replace peak, temporal, or seasonal analysis.
3
Engineer storage separately
Determine retention, treatment, controls, overflow, makeup, and storage from the approved design framework.
4
Check document arithmetic
This worksheet compares the entered supply/demand and required/provided storage without selecting them.

The formula

Maximum daily matched reuse = min(permitted usable supply, eligible demand).
Daily surplus = supply − demand.
Storage ratio = provided storage ÷ engineered required storage.

Worked example

Example
With 80 gal/day permitted usable supply and 65 gal/day eligible demand, maximum matched reuse is 65 gal/day and arithmetic surplus is 15 gal/day. If engineered storage is 100 gal and 120 gal is provided, the ratio is 1.20.

When this estimate will be off

  • Does not estimate occupant generation, permitted greywater sources, eligible uses, fixture demand, temporal coincidence, seasonal demand, or potable makeup.
  • Does not determine treatment, water quality, retention, tank sizing, overflow, drainage, cross-connection control, backflow protection, monitoring, commissioning, or maintenance.
  • Daily matched reuse and annualized arithmetic are not a simulation of storage operation or guaranteed potable-water savings.
  • A provided tank no smaller than an entered requirement is not permit, public-health, plumbing, or system approval.

Frequently asked questions

A common mistake: Does not estimate occupant generation, permitted greywater sources, eligible uses, fixture demand, temporal coincidence, seasonal demand, or potable makeup.

No. Required storage must come from the approved system design and jurisdictional criteria; the worksheet only compares it with provided storage.

Not universally. Definitions, permitted sources, treatment, and end uses vary by jurisdiction and system type.

No. Multiplying by days is only an upper arithmetic bound; timing, seasonality, storage, downtime, treatment losses, overflow, and makeup water affect realized savings.

Sources

This free Greywater System Sizing Calculator is built and maintained by DataDrivenAEC, using the relevant codes and standards. It does not substitute for professional judgment.